Skip to content

Passive Fire Protection Services in UAE

Ibtikar Fire Proofing is a Civil Defence approved passive fire protection contractor in Dubai, Abu Dhabi, Sharjah and the Northern Emirates. We apply intumescent and cementitious fireproofing to structural steel, cable protective coatings, and fire retardant treatments for wood and fabric.

Updated November 2026 · Ibtikar Fire Proofing QC team

850+
Fireproofing projects completed in the UAE
7
Emirates covered, from Abu Dhabi to the Northern Emirates
7
Approvals: Civil Defence in Abu Dhabi, Dubai and Sharjah, ADNOC, CMW, PGC and Tawazun

What is passive fire protection?

Passive fire protection (PFP) is built into the structure. It does not need to be switched on: it keeps steel standing, slows the spread of fire and smoke, and buys time for people to leave and for firefighters to work. Fireproofing on structural steel, fire-rated walls and floors, fire doors and firestopping are all passive fire protection.

Passive · built in

Always in place

Intumescent and cementitious fireproofing, cable coatings, fire-rated walls, doors and firestopping. Measured in minutes of fire resistance or in a reaction-to-fire class.

Active · responds

Has to detect and react

Sprinklers, fire alarms, smoke extraction and extinguishers. They need power, water or a person to work.

The UAE Fire and Life Safety Code of Practice requires both. Whether a building is sprinklered is one of the factors that set the fire ratings its structure needs.

Our passive fire protection systems

Not sure which one fits? Compare fire rated and fire retardant paint.

Fire ratings and test standards

A fire rating is the time an element keeps working in a standard furnace test: 30, 60, 90, 120, 180 or 240 minutes. It belongs to a tested system (the product, the steel section and the thickness applied), not to a product on its own.

Cellulosic fire · buildings

Offices, homes, malls, hotels, warehouses

Tested on the standard ISO 834 fire curve: BS 476-20/21, EN 13381-8 for intumescents, EN 13381-4 for cementitious sprays and boards, and UL 263 / ASTM E119.

Hydrocarbon fire · industry

Oil and gas, petrochemical, power

Burning fuel heats far faster. Tested to UL 1709, the EN 1363-2 hydrocarbon curve and ISO 22899-1 for jet fires. Epoxy intumescent or cementitious systems are used.

The full explanation, with UAE construction types, height categories and how a rating becomes a coating thickness, is in our UAE Fire Rating Guide. Check section factors with the free Hp/A calculator.

Approvals

Ibtikar Fire Proofing is approved by Civil Defence in Abu Dhabi, Dubai and Sharjah, and by ADNOC, the Command of Military Works (CMW), the Presidential Guard Command (PGC) and Tawazun Industrial Park.

Sectors and recent projects

See all fireproofing projects.

How we work

  1. Drawings and BOQ reviewSend structural drawings, the steel member list or BOQ, and the required fire rating.
  2. Hp/A and DFT calculationWe work out the section factor of each member and the dry film thickness the rating needs.
  3. Material submittalProduct data, approvals and the method statement go to the consultant for approval.
  4. ApplicationPrimer condition is checked, then trained crews apply the system with wet and dry film checks.
  5. Inspection and handoverDFT readings, material certificates and inspection reports, ready for the Civil Defence inspection.

Send your fire strategy and steel list

Tell us the fire ratings, the steel sections and the location. We reply within one working day.

Passive fire protection FAQs

What is passive fire protection?

Passive fire protection is fire protection built into a building: fireproofing on structural steel, fire-rated walls, floors and doors, cable coatings and firestopping. It works without being switched on, keeping the structure standing and slowing the spread of fire and smoke.

What is the difference between passive and active fire protection?

Passive fire protection is part of the structure and is always in place. Active fire protection, such as sprinklers, alarms and smoke extraction, has to detect a fire and respond. UAE buildings use both.

Which passive fire protection does structural steel need?

Structural steel is usually protected with thin-film intumescent paint for 30 to 120 minutes, or with cementitious spray for heavy sections and ratings up to 4 hours. Oil, gas and petrochemical projects use epoxy intumescent tested to hydrocarbon fire standards.

Is passive fire protection required in the UAE?

Yes. The UAE Fire and Life Safety Code of Practice sets fire resistance ratings for the structure according to the building’s construction type, use, height and sprinkler protection. The approved fire strategy lists the rating for each element, and Civil Defence inspects the work.

Who can apply passive fire protection in the UAE?

Contractors approved by Civil Defence, using products with a current UAE Civil Defence certificate of conformity. Oil, gas and military clients also require their own contractor approvals. Ibtikar Fire Proofing holds approvals from Civil Defence in Abu Dhabi, Dubai and Sharjah, ADNOC, CMW, PGC and Tawazun Industrial Park.

How long does passive fire protection last?

Intumescent coatings on interior steel typically last 15 to 25 years with an intact topcoat, subject to regular inspection. Damage from later works, such as new fixings or services, should be repaired with the same system.