Skip to content

Section Factor (Hp/A) Calculator

Work out the section factor (Hp/A) of a steel member in seconds. Fireproofing thickness is read from the product’s certified loading table at this Hp/A, the fire rating and the critical steel temperature.

1. Section
2. Fire exposure and protection
– m-1
Heated perimeter – mm · Area – cm²

Calculated with simplified formulas that ignore root radii and corner rounding. For design, use the Hp/A in the manufacturer’s section tables (for example EN 13381-8 / BS 476 loading tables) and the product’s certified data. This tool does not set a coating thickness.

Need the coating thickness for your steel list? Send it to Ibtikar and our QC team will return a DFT schedule from the approved product’s loading table.

What is the section factor (Hp/A)?

The section factor is the heated perimeter of a steel member (Hp, in metres) divided by its cross-sectional area (A, in square metres), so its unit is m-1. A light, thin section has a high Hp/A and heats up quickly in a fire. A heavy section has a low Hp/A and heats up slowly.

Fireproofing manufacturers publish certified loading tables for each product. The dry film thickness (DFT) of an intumescent coating, or the thickness of a cementitious spray or board, is read from that table using three inputs: the section factor, the fire rating (for example 60, 90 or 120 minutes) and the critical (design) steel temperature.

Profile or box protection?

Intumescent coatings and spray-applied cementitious products follow the shape of the steel, so the heated perimeter is the full outline of the section (profile). Fire boards are fixed around the section like a box, so the heated perimeter is the box outline. A beam that supports a concrete slab is heated on three sides, so the top flange is left out of the perimeter.

Need a DFT schedule for your project?

Ibtikar Fire Proofing is a UAE Civil Defence approved passive fire protection contractor. Send us your steel list and fire ratings, and our QC team will prepare a DFT schedule from the loading table of the approved product. Contact us or see our intumescent coating and cementitious fireproofing services.