Fire Rated & Fire Retardant Paint in UAE
Civil Defence approved fire rated paint (intumescent coating) for structural steel, and fire retardant paint and treatments for wood and fabric. Supplied and applied by Ibtikar Fire Proofing in Dubai, Abu Dhabi, Sharjah and the Northern Emirates.
Which fire paint does your project need?
Start with what you need to protect. Steel needs a fire rating in minutes; wood and fabric need a reaction-to-fire class. They are different products, tested in different ways.
Fire rated paint (intumescent)
Keeps beams and columns load-bearing for 30 to 120 minutes. Water-based for interiors, solvent-based or epoxy for harsher conditions.
Intumescent paintsFire retardant paint for wood
Slows ignition and flame spread on timber, doors and panelling while keeping the wood’s natural look.
Wood fire retardantFire retardant treatment for fabric
For curtains, upholstery and soft furnishings in hotels, malls and offices, to meet fire safety codes in commercial fit-outs.
Fabric fire retardantCable protective coating
A fire-resistant coating for cable trays that stops flame spreading along the cables and keeps critical circuits running.
Cable protective coatingFire rated vs fire retardant vs fire resistant paint
These names are often used as if they mean the same thing. They do not, and the difference matters at the Civil Defence inspection.
| Fire rated (fire resistant) paint | Fire retardant paint | |
|---|---|---|
| Also called | Intumescent paint, fireproof paint, fire resistant coating | Flame retardant coating, fire retardant treatment |
| What it does | Swells into an insulating char at about 200–250 °C and keeps steel below its critical temperature | Slows ignition and flame spread across a surface |
| Result | Minutes: 30, 60, 90, 120 (R30 to R120) | A class: A1 to F, Class 0 or Class A |
| Typical tests | BS 476-20/21, EN 13381-8, UL 263 / ASTM E119 | BS 476-6/7, EN 13501-1, ASTM E84 |
| Used on | Structural steel beams, columns and trusses | Wood, boards, fabric and interior finishes |
| Gives steel a fire rating? | Yes, at the tested thickness | No |
Fire rated paint for structural steel
Fire rated paint for steel is an intumescent coating. When the steel heats to about 200–250 °C, the coating expands 50 to 100 times its applied thickness into a char that insulates the steel. Thin-film systems usually give 30 to 120 minutes, and 180 minutes only on specifically tested systems.
The thickness is not a single figure. It is read for each member from the product’s certified loading table, using the fire rating, the section factor (Hp/A), the critical steel temperature and the test standard. Work out Hp/A with our free section factor calculator, and see how ratings are set in the UAE Fire Rating Guide.
Water-based intumescent
Low odour, for interior steel in offices, malls, schools and warehouses.
Intumescent paintsSolvent-based intumescent
Fast curing, for exposed steel, humid conditions and tight programmes.
Solvent intumescent coatingEpoxy intumescent
For hydrocarbon fire ratings tested to UL 1709, and for offshore, marine and heavy industrial steel.
Epoxy intumescentNeed 3 or 4 hours on heavy sections hidden behind ceilings? Cementitious fireproofing is usually the better choice.
Fire retardant paint for wood, fabric and boards
Fire retardant products are rated on reaction to fire: how quickly a surface ignites and how far flame spreads across it. They are used on combustible interior finishes such as timber cladding, doors, panelling, boards, curtains and upholstery, where the fire strategy or the fit-out specification asks for a flame-spread class.
- Wood: clear or paintable fire retardant treatments for timber and wood-based boards. See wood fire retardant.
- Fabric: fire retardant treatment of curtains, upholstery and soft furnishings. See fabric fire retardant.
- Check the class: confirm the class the specification asks for (for example Class 0, Class A or B-s1,d0) and that the treatment was tested on the same kind of material.
What UAE Civil Defence checks
- The product has a current UAE Civil Defence certificate of conformity that covers that exact product.
- The thickness comes from test data to the standard the specification names (for example BS 476 or EN 13381-8) and is shown on a DFT schedule the consultant has approved.
- The work is applied by an approved applicator, and the DFT of every member is measured and recorded.
- Material certificates, DFT records and inspection reports are ready before the site inspection.
Ibtikar Fire Proofing holds Civil Defence approvals in Abu Dhabi, Dubai and Sharjah, and approvals with ADNOC, CMW, PGC and Tawazun Industrial Park:
Brands we apply
We apply certified systems from leading manufacturers, including Nullifire, Hempel (Hempafire), Phoenix, Carboline and International (Interchar). Data sheets and certificates are on Fireproofing Materials & Data Sheets.
How we work
- Drawings and BOQ reviewSend structural drawings, the steel member list or BOQ, and the required fire rating or class.
- Hp/A and DFT calculationWe work out the section factor of each member and the dry film thickness the rating needs.
- Material submittalProduct data, approvals and the method statement go to the consultant for approval.
- ApplicationPrimer condition is checked, then trained crews apply the system with wet and dry film checks.
- Inspection and handoverDFT readings, material certificates and inspection reports, ready for the Civil Defence inspection.
Send your drawings for a fire paint quote
Tell us what needs protecting, the fire rating or class, and the area. We reply within one working day.
Fire rated and fire retardant paint FAQs
What is the difference between fire rated and fire retardant paint?
Fire rated paint, usually an intumescent coating, keeps structural steel load-bearing for a set time in a fire, for example 60 or 120 minutes. Fire retardant paint slows ignition and flame spread on surfaces such as wood and fabric. Only fire rated paint gives steel a fire rating.
Can fire retardant paint be used on steel?
Not to meet a fire rating. Steel that needs R30 to R120 must be protected with intumescent or cementitious fireproofing, applied at the thickness given in the product’s certified loading table.
How long does fire rated paint protect steel?
Thin-film intumescent paint usually gives 30 to 120 minutes, and 180 minutes only on specifically tested systems. For 3 to 4 hours in buildings, cementitious fireproofing is the usual choice. Epoxy intumescents tested to UL 1709 reach up to 4 hours against hydrocarbon fires.
Does fire rated paint need Civil Defence approval in the UAE?
Yes. The product needs a current UAE Civil Defence certificate of conformity, the consultant approves the DFT schedule, and the work is inspected before handover. Ibtikar Fire Proofing is a Civil Defence approved fireproofing contractor in Abu Dhabi, Dubai and Sharjah.
How thick is fire rated paint?
There is no single thickness. It is read for each steel member from the product’s certified loading table, using the fire rating, the section factor (Hp/A), the critical steel temperature and the test standard. Lighter sections and higher ratings need more paint.
Can fire rated paint be used outdoors?
Yes, with the right system. Solvent-based or epoxy intumescent coatings with a suitable topcoat are used for exposed or humid conditions, and epoxy intumescent is the usual choice for marine and offshore steel.
How is fire rated paint priced in the UAE?
It is priced per square metre of steel surface and depends on the fire rating, the thickness each member needs, the product, access and quantity. Send drawings or a steel member list and the required rating, and we will reply with a quote within one working day.