Emtelle Blown Fibre and Ducted Network Cable Manufacturing Facility

Intumescent coatings offer a cutting-edge solution for fireproofing steel structures. These thin, water-based coatings expand significantly when exposed to heat, forming a thick, insulating char that protects steel from fire damage. This innovative technology provides several benefits for critical infrastructure projects:

  • Minimal Disruption: Intumescent coatings require minimal preparation and cure quickly, minimizing downtime during construction.
  • Enhanced Aesthetics: Available in a variety of colors and finishes, they can complement the building’s design without bulky coverings.
  • Superior Corrosion Protection: Certain intumescent coatings offer additional protection against corrosion, ideal for sensitive equipment like fiber optic cables.

Project Details

  • Project Name: Emtelle Blown Fibre and Ducted Network Cable Manufacturing
  • Fireproof Material: Nullifire SC802 and Nullifire SC804
  • Fireproof Type: Intumescents
  • Project Location: Abu Dhabi
  • Applied On: Steel Structure
  • Fire Rated Requirement: 1 Hour Fire Rated

Nullifire SC802 and Nullifire SC804 : Exceptional Fire Protection

Nullifire SC802 and SC804: Fireproofing Innovation for Steel Structures

Nullifire SC802 and SC804 are high-performance intumescent coatings designed to provide superior fire protection for internal steel structures. Both products fall under the Nullifire brand, a trusted name in fireproofing solutions. Here’s a breakdown of their key features:

Similarities:

  • Fireproofing Type: Both SC802 and SC804 are water-based, single-component intumescent coatings. This translates to easier handling, faster drying times, and lower environmental impact compared to solvent-based options.
  • Application: They are spray-applied, offering a smooth and aesthetically pleasing finish.
  • Fire Resistance: Both can achieve up to 1-hour fire resistance for specific section sizes and thicknesses (refer to Nullifire’s technical data sheets for detailed information).
  • Certifications: They likely hold relevant fire safety certifications required in the UAE (check specific product information for confirmation).

Potential Differences (consult Nullifire product data sheets for specifics):

  • Loading Requirements: SC802 and SC804 might cater to different fire protection needs based on the weight (loading) they can handle on specific steel sections. For example, SC802 might be suitable for lighter structures, while SC804 might offer protection for heavier beams and columns.
  • Aesthetics: While both offer a smooth finish, SC804 might have a wider range of available topcoat options for enhanced aesthetics in exposed areas.

Applications:

These intumescent coatings are ideal for various projects involving internal steel structures that require fire protection, such as:

  • Industrial buildings
  • Warehouses
  • Commercial buildings
  • Car parks
  • Data centers (when appropriate intumescent type is selected)

Choosing Between SC802 and SC804:

The best choice between SC802 and SC804 depends on your specific project requirements. Consider factors like:

  • Fire rating requirement
  • Steel section sizes and weight loads
  • Desired aesthetics
  • Project specifications and fire code compliance

Ibtikar’s Commitment to Fire Safety

Ibtikar’s expertise in fireproofing was instrumental in the successful completion of Phase 2 of the KEZAD Light Industrial Units project. Our team utilized a meticulous spray application process to ensure even and complete coverage of the steel structures with Pyrolite 15. Our fireproofing specialists possess in-depth knowledge of local building codes and fire safety regulations, guaranteeing compliance with the project’s 2-hour fire rating requirement. A unique aspect of this project involved [ Briefly describe a specific challenge or unique solution implemented by Ibtikar. Ex: coordinating fireproofing with tight construction deadlines or incorporating fireproofing into a complex architectural design]. This demonstrates Ibtikar’s adaptability and ability to deliver exceptional fireproofing solutions for any project.

  • Should I use passive fireproofing or active fireproofing systems in my new warehouse in Dubai?

This question targets both warehouse owners and those searching for fireproofing information in Dubai. It highlights the two main fireproofing categories and positions Ibtikar as a company with the knowledge to navigate this decision-making process.

  • Water-based vs. Solvent-based Intumescents: Which is right for my project?

A: Choosing between water-based and solvent-based intumescents depends on your project’s specific needs. Here’s a breakdown:

  • Water-based intumescents:
    • Eco-friendly and low odor, ideal for indoor applications.
    • Faster drying times.
    • May have lower durability compared to solvent-based options.
  • Solvent-based intumescents:
    • Offer enhanced fire resistance and durability, suitable for harsh environments.
    • More resistant to moisture and weather extremes.
    • Can have a stronger odor, requiring proper ventilation during application.
  • Consider these factors when making your choice:
  • Project location (indoor vs. outdoor)
  • Desired fire rating
  • Environmental conditions
  • Application limitations (ventilation needs)